Drone Ag Limited // Operating Safety Case
Test Results - DJI T50 - Laminex
Client: Global Adjuvants
Product: Laminex
Ā
Required Items Checklist
Materials and Equipment:
Drone and Accessories:
Testing Substances:
Note: 1 batch completed as ground test + 1 batch completed as aerial test
Other Equipment:
clothing)
Documentation Tools:
Ā
Test Results
Location: Farm ground site
Date: 20th February 2025
Testing Staff: Alex-Macdonald-Smith, Jack Wrangham
Ā
Environmental Assessment
Weather in general: Dry and windy
Wind Speed: High
Temperature: 10 deg c
Ground Test
Adjuvant was mixed at 1 litre to 15 litres of water, 16L total loaded into drone spray tank
Spray system was initiated and cleared of air allowing both nozzles to operate
Spray test was initiated, beginning with the most coarse droplet setting (500 um)
Spray test was then conducted at each droplet setting down to the finest setting (50 um)
Consistent flow was observed at all droplet settings
Even spray distribution was observed at all droplet settings
No signs of blockage were observed at all droplet settings
After spray test, filters did not appear clogged
Minor residue was observed in tank filter, easily washed out
Ā
After washdown and rinse through, clear water came through the system with no signs of blockage or residue
Once the system was emptied of water, tank filters were checked with no signs of blockage or residue
Ā
Ā
Ā
Flight Test
Location: Farm field site
Date: 02th May 2025
Testing Staff: Alex-Macdonald-Smith, Jack Wrangham
Ā
Environmental Assessment
Weather in general: Dry with mild wind
Wind Speed: less than 3mph
Temperature: 17 deg c
Ā
Ā
Spray system was initiated and cleared of air allowing both nozzles to operate
Flight was initiated, 2.5m height above crop, 5m row width
Flight spray test was initiated, beginning with the most coarse droplet setting (500 um)
Flight spray test was then conducted at each droplet setting down to the finest setting (50 um)
Consistent flow was observed at all droplet settings
Even spray distribution and minimal drift was observed at all droplet settings
No signs of blockage were observed at all droplet settings
Ā
Ā
Ā
Ā
Ā
Ā
Related content
Drone Ag Limited // Version 2.5.1 // 28/10/2024
Ā© Drone Ag Limited ā 2024
All rights reserved. Reproduction of this publication is not permitted by any person without the expressed permission of the Accountable Manager of Drone Ag Limited.